Didn't the fans circulate air through the cabinets?
If so, and there were cobwebs, then those were some *determined* spiders!
Didn't the fans circulate air through the cabinets?
If so, and there were cobwebs, then those were some *determined* spiders!
@weekend_editor @dfupdate It has been powered of for a long time. Today we had it running and played with the console, but unfortunately no data from the tape would load into memory.
@tastytronic Long shot, but do you have any inkling why the tape transfer wouldn't work? The console seems fine. Exam/fill works. Toggling in and stepping or running short programs is ok. Running an RCG 7300 spins the tape in a satisfactory manner. Yet nothing in the memory is updated. We filled memory with a distinct pattern and checked it was still all there. @larsbrinkhoff
@tastytronic Does PROGOFOP need to be loaded manually first?
@larsbrinkhoff Zach and I are chatting about this, stay tuned. But have you tried the other tape unit? Or a different tape?
@larsbrinkhoff Are you trying to read individual blocks using RDE, RDC, or RDG? You should be able to (using the console) ask it to read a specific block number from tape to memory. RDC will check it, supposedly. If the tape drive runs and completes, then that suggests at least that tape logic is working but tape data transfer might not be. (As opposed to running but not stopping, or not running at all.) Again, I would try a different tape and/or the other tape physical drive. I guess it's possible that a different tape unit number could be worth trying but I doubt that's the issue.
@larsbrinkhoff You could also jump onto the VCF forums if you aren't already doing that. If you post in our thread for PDP-12 #435 (https://forum.vcfed.org/index.php?threads/pdp-12-435-at-the-university-of-minnesota-duluth.1241469/page-33#post-1523886) you could either ask there, or make your own thread for the Update PDP-12, and ask interested people to join. There are several PDP-12 experts.
@mthompson and @davefischer any other suggestions for Lars?
@larsbrinkhoff @mthompson @davefischer Zach isn't on Mastodon (yet) but he writes:
"I'd be curious if running a read insn to spool the tape from one end to the other and vice-versa behaves as expected and if reading close blocks results in minimal movement
if that behaves as expected, I think the TC12 must be getting the timing track and block number info
the latter I think would mean its getting data off the main data channels in general "
@larsbrinkhoff @mthompson @davefischer We have also had weird issues get resolved by cleaning / reseating the tape cables. We had one bug where one of the wires in the tape cables was intermittently shorting, so we added a bodge wire on the outside of the cable.
@larsbrinkhoff @mthompson @davefischer You can switch which drive is directly connected to the PDP-12 and which one is connected by the passthrough, or you can leave the passthrough drive disconnected altogether. By trying different configurations, you should be able to determine if the behavior you see is tied to a specific drive or cable.
@tastytronic @mthompson @davefischer The tape movement did seem proportional to the amount needed to find a far or close block.
@tastytronic Mostly we wanted to boot into LAP6, so toggled in RCG 7300. The drive spun the tape, and it seemed plausible it was seeking to block 300.
@tastytronic Yes, we tried both drives and various tapes.