Login
You're viewing the ruby.social public feed.
  • Nov 28, 2026, 2:03 PM

    @anymouse_404 @lanodan
    In other words, most of the time URE means the drive tried to read the data from the magnetic flux of the platter, failed, did multiple failed retries, and timed out.

    I think most of the time it's because the bits decoded form the platter were not a valid codeword in the drive's internal ECC - it detected an error but couldn't correct it.

    But I guess it could be other things, like not being able to find the track or sth.

    💬 1🔄 0⭐ 0

Replies

  • Nov 28, 2026, 2:07 PM

    @anymouse_404 @lanodan
    If you use RAID, you likely set the drive's timeout (SCTERC) very low, so that you get to try the other drive instead of waiting multiple seconds while the first drive keeps trying.

    So it's possible that with the default timeout, the drive would succeed.

    But I'm not sure if host-level retries are independent events, each with 10^-15 * sector_size_in_bits probability

    💬 0🔄 0⭐ 0