  • Aug 26, 2026, 2:11 AM

    The Enerdrive worked perfectly well with the old 100Ah battery, but with the new 314Ah battery, it keeps switching from constant current (CC) to constant voltage (CV) well before it should. But it has a manual "Program" mode with higher voltage allowances than the Lithium mode, so I write instructions for them to switch to it, and its even worse. The two stage mode under Program switches from CC to CV and then to float, a charging stage that it's only meant to go to in the three stage mode. It's not pushing voltages dangerous to the battery, but its not pushing enough current to actually charge the battery, so after days of monitoring I recommend that it be switched back to Lithium mode.

    Switch made, and oh, it's retained the messed up setting. Fine, let's completely reset it, but no. It's stuck with a Lithium mode that features a float stage.

    Guess we're upgrading to Victron.